10 cu-ft incubator environmental room
Larger image

Conditioned environmental room for robotic assembly.
Larger image

Three compartment stability environmental test room shares common
insulated walls, thus reducing overall costs.
Larger image
|
|
Environmental rooms are ideal for steady state temperature and
humidity testing, stability and shelf life testing, cold room labs,
and incubation. Rooms can be designed to include heating, refrigeration,
humidification, dehumidification, and lighting to accommodate a
variety of applications.
Lunaire's expertise in environmental rooms control allows you to
specify an environmental room in any configuration to perfectly
fit your needs. From conception, our engineers will work with you
to analyze your requirements, develop an efficient system, and design
a room that is logical in application as well as sturdy, durable,
and functional.
Our flexible, interlocking panelized construction can easily accommodate
any arrangement and a variety of heights. The strong, lightweight
panels provide optimum insulation, the stability to add on or rearrange,
and years of worry-free service. Conveniently located control panel
allows easy monitoring of all room functions, while state-of-the-art
controls provide precise regulation of the simulated environment.
Custom-engineered room with complete programming
of temperature, humidity, and light intensity. The airflow is vertical
down through a raised stainless floor.
Tongue-and-groove panel incorporates an inherent thermal break
that eliminates the possibility of metal-to-metal transfer of heat
from the interior to the exterior. Cam lock fasteners draw opposing
panels tightly together for an impenetrable seal and permit quick
assembly.
Features
- Textured or smooth aluminum in painted white or natural mill
finish as well as stainless clad panels that feature 4" foamed-in-place
polyurethane insulation. This manufacturing process not only increases
the thermal integrity of the room, but also adds synergistic strength
to the panel.
- Room panels can be easily rearranged and panels can be added
to accommodate expansion to the room. Depending upon the application,
rooms are designed with ceiling or wall conditioning systems to
provide even, uniform airflow.
- For heating, cooling, humidification, or dehumidification, air
is circulated through a conditioning plenum in both ceiling and
wall systems.
- Our systems are precision-engineered to provide maximum airflow
uniformity as well as extremely quiet operation.
- Floors are 16 gauge galvanized steel, designed to support 500
lbs. per square foot.
- Custom engineering for out-of-the-ordinary applications is one
of our specialties.
- Accurate microprocessors based digital set and readout controls
are standard.
- Depending upon the application, options such as programmable
controls, timing devices, chart recorders, and computer interfacing
are available.
Wall System
The wall plenum system provides superior airflow control and is
typically used where highly uniform conditions are required. Wall
systems can be rear or side mounted. Typical airflow is accomplished
by means of a full ceiling-mounted air distribution unit that circulates
the conditioned air vertically downward through the room and returned
to the wall conditioning plenum via the return air grill at floor
level. Wall systems provide temperature uniformity up to +/- 0.3°C
as well as expanded temperature and humidity ranges.
Ceiling System
Ceiling systems are typically used when floor space, furniture,
or loading arrangement constraints prohibit use of a wall plenum.
A factory modified, low velocity unit cooler in the ceiling plenum
conditions the air, which is discharged into a full ceiling air
distribution unit. The air is circulated vertically downward through
the room and returned to the center or rear return air section of
the unit cooler. The economical ceiling system is generally limited
to moderate humidity requirements and temperature uniformity of
+/- 0.75°C.
Stability Test Chambers
- Meets all present and future ICH guidelines.
- A large selection of standard chamber sizes: 10, 17, 32, 41,
58 cu. ft.
- Available in four temperature or temperature and humidity combinations.
- Chambers can be equipped with optional lighting systems for
photostability testing.
- Assistance with IQ/OQ protocols or complete chamber validation
is available.
- Optional computer interface with Windows-based software for
multiple chamber monitoring.
- Ideal for stability, shelf life, burn-in, and reliability testing;
curing; and controlled temperature storage.
Forced Air Ovens
- Offer workspace of 1, 3, 5, 10, 15, 28 cu. ft.
- Are capable of temperatures of 10 degrees above ambient to 300
degrees C.
- Timed cycle operation, programmable up to 99 hours.
- Chambers are equipped with solid stainless steel shelves.
- Optional recording instruments, windows, casters, and support
stands.
- Ideal for shelf life, stability, burn-in, and reliability testing;
drying, curing, and aging.
All rooms are available through Lunaire's Leasing
program.
|
|
|